Elimko TC02-1S5Y15-50 Type S Platinum Thermocouple Ceramic Tube Ø15 × 500 mm

Elimko TC02-1S5Y15-50 Type S Platinum Thermocouple Ceramic Tube Ø15 × 500 mm

  • Brand: Elimko
  • Product Code: TC02-1S5Y15-50

Prices are prepared per project according to capacity, energy type and delivery terms.

Elimko TC02-1S5Y15-50 is a straight-type single-element type S (Pt%10Rh-Pt (IEC 60584)) platinum thermocouple, Ø15 mm, with 500 mm immersion length. The gas-tight KER 610 ceramic tube protects the platinum element from furnace gases. Thermal shock resistance is medium; insert and withdraw slowly.

Platinum thermocouples are far more stable than type K above 1200 °C, so they are used in ceramic, glass, sintering and high-temperature heat-treatment furnaces. The platinum element is sensitive to metal vapours and reducing atmospheres; the right protection tube determines its life.

Technical data

Order codeTC02-1S5Y15-50
DesignTC02 – high-temperature straight type with ceramic protection tube
ElementSingle, type S, Pt%10Rh-Pt (IEC 60584), wire diameter 0.5 mm
Measuring range (type)0 … 1500 °C
Protection tubeKER 610 special porcelain ceramic (gas-tight)
Tube outer diameter15 mm
Inner tube—
Immersion length500 mm
Temperature limitsElement: 1300 °C continuous, 1600 °C short-term (Ø0.5 mm wire) · Tube limit: 1500 °C
Usable upper limit1500 °C (lower of tube and element limits, short-term)
Connection headAluminium head (A/B/C); head temperature max. 200 °C
Extension cableUse the matching S/R compensating cable

Order code structure: TC0x – number of elements + type (S/R/B) + wire diameter + tube material + tube diameter – length (cm) – inner tube (PY: KER 610, PZ: KER 799). Tube material codes: X = KER 530, Y = KER 610, Z = KER 799, I = Inconel. Ask for type B (Pt30%Rh-Pt6%Rh), dual elements, flanges and calibration certificates.

Technical data is based on the Elimko catalogue (Straight Type Thermocouples, Thermocouple General Information) and is for information only. Elimko thermocouples are made to order; we define the order code together at quotation stage for other lengths, diameters, protection tubes, inner tubes, flanges and heads. Temperature limits apply in air without harmful gases; they are lower in reducing or corrosive atmospheres.

For price and lead time, use the Request a Quote button or call +90 533 945 27 94.

Tags: Elimko TC02-1S5Y15-50, type S thermocouple, platinum thermocouple, ceramic tube thermocouple, high temperature thermocouple, 500 mm, Elimko